Style 2BF has a hex nipple fixed in position and contains the transition from sheath wire to insulated wire. Typically, the flexible, insulated leads connect to a thermocouple head or a remote location. Optional thermocouple heads may be ordered with this style.
|
STYLE 2BSPRING-LOADED
Click Picture for Catalog Cut Sheet |
Part Number and Quote Request |
| SHEATH TYPE THERMOCOUPLE WITH SS HEX NIPPLE ADJUSTABLE TO DESIRED 'U' DIMENSION, FLEXIBLE INSULATED LEAD WIRE, 20ga. STANDARD, OTHER GAUGES AVAILABLE UPON REQUEST. | ||
![]() |
||
| Accessories: Spring-Loading, Reduced Tip, or Weld Pad. | ||
Style 2BS has a spring-loaded hex nipple. The transition from sheath wire to insulated wire is contained in a smooth transition equal to the O.D. of the sheath. A spring-loaded assembly is often used with a thermowell to ensure contact of the thermocouple tip with the bottom of the thermowell. The flexible insulated lead is connected to a thermocouple head or a remote location. A thermocouple head may be ordered as an option with this style.